ADT SAFEWATCH PRO 3000 PROGRAMMING MANUAL Pdf Download (2024)

ADT SAFEWATCH PRO 3000 PROGRAMMING MANUAL Pdf Download (1)
  1. Manuals
  2. Brands
  3. ADT Manuals
  4. Security System
  5. Safewatch Pro 3000
  6. Programming manual

Hide thumbs Also See for Safewatch Pro 3000:

  • User manual (57 pages)
  • ,
  • Installaton manual (88 pages)
  • ,
  • System manual (14 pages)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
  • Contents
  • Table of Contents
  • Bookmarks

Advertisem*nt

Table of Contents

  • 1 To Enter Programming Mode
  • 2 To Exit Programming Mode
  • 3 Output Definitions
  • 4 Zone Type Definitions
  • 5 ALPHA VOCABULARY LIST (for Entering Zone Descriptors)
  • 6 CHARACTER (ASCII) CHART (for Adding Custom Words)
  • 7 5800 Series Transmitter Input Loop Identification
  • Download this manual

See also: System Manual , User Manual

K5305PRV1 5/01

1

2

3

ARMED

OFF

AWAY

STAY

4

5

6

READY

TEST

BYPASS

7

8

9

INSTANT

CODE

CHIME

#

READY

ARMED

READY

6DIHZDW.K3UR

6H.XULW\0DQDJHU

3URJUDPPLQJ*XLGH

1

2

3

OFF

AWAY

STAY

5

6

4

TEST

BYPASS

8

9

7

INSTANT

CODE

CHIME

#

READY

Š

Model SASW3000B

Table ofContents

NextPage
  • 1
  • 2
  • 3
  • 4
  • 5

Advertisem*nt

Table of Contents

ADT SAFEWATCH PRO 3000 PROGRAMMING MANUAL Pdf Download (2)

Related Manuals for ADT Safewatch Pro 3000

  • Security System ADT Safewatch Pro 3000 Installaton Manual

    (88 pages)

  • Security System ADT Security Manager 3000 User Manual

    Adt safewatch pro 3000 security manager 3000 security system user's guide (57 pages)

  • Security System ADT Safewatch Pro 3000 System Manual

    (14 pages)

  • Control Panel ADT SafeWatch 3000 Battery Replacement Instructions

    Residential control panels (4 pages)

  • Security System ADT PremisePro none User Manual

    Adt security services premisepro user manual (24 pages)

  • Security System ADT Safewatch Pro 2000 User Manual

    Adt user guide firealarm savs20adt-1 (48 pages)

  • Security System ADT Safewatch Pro 2000 User Manual

    (49 pages)

  • Security System ADT Garda Response PM30 Reference Manual

    Alarm panel and keypad (17 pages)

  • Security System ADT K5309V2 User Manual

    Adt security services k5309v2 user guide (57 pages)

  • Security System ADT SASW3000EN User Manual

    Safewatch pro 3000en/ enterpreneur 3000en/ security manager 3000en (64 pages)

  • Security System ADT Safewatch Pro 3000EN Installation And Setup Manual

    (104 pages)

  • Security System ADT Smart Home PM360-R Quick Consumer Reference Manual

    (13 pages)

  • Security System ADT Smart Home PM360 Quick Consumer Reference Manual

    (12 pages)

  • Security System ADT FOCUS 200 PLUS Installation And Setup Manual

    Commercial fire and burglary security system with scheduling (216 pages)

  • Adt security services commercial fire & burglary alarm system user guide (88 pages)

  • Security System ADT Focus 200 Plus User Manual

    Adt focus 200 plus commercial fire and burglary alarm system user guide (88 pages)

Summary of Contents for ADT Safewatch Pro 3000

  • Page 1 6DIHZDW.K3UR Š 6H.XULW\0DQDJHU 3URJUDPPLQJ*XLGH ARMED AWAY STAY READY TEST BYPASS INSTANT CODE CHIME READY ARMED AWAY STAY READY TEST BYPASS INSTANT CODE CHIME READY K5305PRV1 5/01 Model SASW3000B...
  • Page 2: To Enter Programming Mode

    TO ENTER PROGRAMMING MODE: Local programming requires the use of a Custom English touchpad connected to the touchpad terminals on the control. ✱ 1. POWER UP, then depress [ ] and [#] both at once, within 50 seconds of powering up. 2.
  • Page 3 352*5$00,1*)250 Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults. Field Function Data Entries Programmable Values SYSTEM SETUP ( ✱ 20– ✱ 29) ∗ 20 4 digits, 0–9 INSTALLER CODE [6321] ✱...
  • Page 4 For fields *43 and *45: Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; [#+15 for F]. To clear entries from field, press * 43 * or * 45 * . Examples: For Acct. 1234, enter: 1 | 2 | 3 | 4 ;...
  • Page 5 RESTORE REPORT CODES ( ✱ 70 – ✱ 76) ✱ 70 ALARM RESTORE RPT CODE Any non-zero entry enables CID report. ✱ 71 TROUBLE RESTORE RPT CODE [10] Any non-zero entry in first digit enables CID report. ✱ 72 BYPASS RESTORE RPT CODE [00] Any non-zero entry in first digit enables CID report.
  • Page 6 PAGER OPTIONS 160-172 ✱ 160 PAGER 1 PHONE No. Enter up to 20 digits. 0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-second pause. ✱ 161 PAGER 1 CHARACTERS Enter the optional prefix characters, up to 16 digits. 0–9;...
  • Page 7 ✱ 177 DEVICE DURATION 1, 2 0 = 15 seconds 6 = 2-1/2 min #+11 = 7 min [0] [0] 1 = 30 seconds 7 = 3 min #+12 = 8 min (used in *80 Menu mode-Device Actions 5/6) 2 = 45 seconds 8 = 4 min #+13 = 10 min 3 = 60 seconds...
  • Page 8 Configurable Zone Types Worksheets Configurable zone types 90 and 91 can be programmed via downloader software or from a touchpad using data fields*182-*185. Configurable zone types 92 and 93 can only be programmed using the downloader software. Programming Configurable Zone Type options involves entering 10 digits in data field *182 for zone type 90 and field *184 for zone type 91, where each digit represents the sum of the values of its various options as shown in the tables below.
  • Page 9 *56 ZONE PROGRAMMING WORKSHEET [default values shown in brackets] Zone Zn Type Part. Report Input Type Loop Rsp. Time Serial No. Location [01] [HW] [01] [HW] [10] [HW] [10] [HW] [10] [HW] [01] [HW] [01] [HW] [01] [HW] [BR] [BR] [BR] [BR] [BR]...
  • Page 10 *57 FUNCTION KEY PROGRAMMING Option Function Comments Paging Time Display Arm AWAY Arm STAY Arm NIGHT-STAY Step Arming Device Activation Device: Comm. Test Macro Key 1 Macro Key 2 Macro Key 3 Macro Key 4 Emergency Keys: Personal Emergency Silent Alarm Audible Alarm Fire Emergency Keys:...
  • Page 11: Output Definitions

    ✱ 80 OUTPUT DEFINITIONS Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence. Notes: 1. For Relays, 4229 and 4204 devices are programmed in *79, *80, and *81 modes. ✱...
  • Page 12: Zone Type Definitions

    Zone Type Definitions Use this zone type if the zone is not used. Type 00 Zone Not Used • Assign to zones that are used for primary entry and exit. Type 01 • Provides entry delay if the control is armed in the Away or Stay modes. Entry/Exit Burglary #1 •...
  • Page 13 • Arms the system in Stay mode when the zone is activated. Type 20 • Pushbutton units send the user number to the central station when arming or disarming. Arm-Stay • User code for button must be assigned. • Arms the system in Away mode when the zone is activated. Type 21 •...
  • Page 14: Alpha Vocabulary List (For Entering Zone Descriptors)

    ALPHA VOCABULARY LIST (For Entering Zone Descriptors) (Word Space) • 057 DOOR – L – – R – – V – • 106 LAUNDRY • 059 DOWN RADIO VALVE – A – VAULT • 107 LEFT • 060 DOWNSTAIRS • 156 REAR •...
  • Page 15: 5800 Series Transmitter Input Loop Identification

    5800 Series Transmitter Input Loop Identification • All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the inputs requires its own programming zone (e.g., a 5804's four inputs require four programming zones). •...
  • Page 16 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ADT Security Services, Inc. • One Town Center Rd. • Boca Raton, FL 33486 Copyright ©...

This manual is also suitable for:

Security manager 3000

ADT SAFEWATCH PRO 3000 PROGRAMMING MANUAL Pdf Download (2024)

References

Top Articles
Latest Posts
Article information

Author: Pres. Lawanda Wiegand

Last Updated:

Views: 6287

Rating: 4 / 5 (51 voted)

Reviews: 82% of readers found this page helpful

Author information

Name: Pres. Lawanda Wiegand

Birthday: 1993-01-10

Address: Suite 391 6963 Ullrich Shore, Bellefort, WI 01350-7893

Phone: +6806610432415

Job: Dynamic Manufacturing Assistant

Hobby: amateur radio, Taekwondo, Wood carving, Parkour, Skateboarding, Running, Rafting

Introduction: My name is Pres. Lawanda Wiegand, I am a inquisitive, helpful, glamorous, cheerful, open, clever, innocent person who loves writing and wants to share my knowledge and understanding with you.